Atlantic City Electric's New Jersey Load Profiles for each rate schedule are derived via one of two methods:

  • where customer hourly-load data is available, the profiles are based on the actual weighted average of the profiled customers in that class
  • where customer load data is not available, the profiles are simulated based on historic data and actual weather.

Refer to the Supplier Operating Manual posted on this site to see how the profiles are used in the calculation of Capacity and Transmission PLC Tickets and Energy Settlement.

Each row begins with the profile name and date followed by the 24 hourly values. The hours correspond to Eastern Standard Time where Daylight Savings time is recognized.
Daylight Savings time is recognized and handled in the following manner.

  • On the 23-hour day each Spring, the "missing" third hour contains the value of "0.00" to hold the space so that the fourth hour on that day represents the hour ending 0400 DST and so forth.
  • On the 25-hour day each Autumn, the second hour contains a copy of the third hour.

The following table provides an index for each of the Profile Ids to the profile used and applicable voltage codes. For further information about Atlantic City Electric's profiling methodology, please refer to the Supplier Operating Manual currently posted on this site.

Rate Class DescriptionLDC Rate ClassProfile CodeVoltage Code
Residential ServiceRSBASICNJARS, NJARNEM*1
Residential Time Of UseRSTOU, RSTOUD, RSTOUNDNJART1
Monthly General Service, SecondaryMGSSECOND, MGSSECONDH, ANMG_UMGSSNJAMS1
Monthly General Service, PrimaryMGSPRIMARY, MGSPRIMARYHNJAMP2, 3, 4
Annual General Service, SecondaryAGSSECOND, AGSSECONDHNJAAS1
Annual General Service, PrimaryAGSPRIMARY, AGSPRIMARYHNJAAP2,3,4
Street and Private LightingANEL_SPL, ANEL_CSL, SPLBASIC, CSLBASICNJAOL1
Direct Distribution Connection - DccDDCBASIC, ANEO_DDCNJADC1
Transmission General ServiceTGSBASICNJAGT4
Transmission General Service Sub TransTGSSUBTRANSNJAGN3
TRANSMISSION GENERAL SERVICE SUB TRANSSCCBASICNJASCC3

* NJARNEM are solar customers with Net Energy Metering.

Note: Individually profiled customers have interval-billing meters providing actual hourly loads for retail settlement.

The following table provides a description of each voltage code and its associated loss factor used in settlement calculations.

Loss Factors​

Energy - For Hourly Energy Obligations Voltage CodeEffective 6/1/2014
Secondary11.07149
Primary21.04345
Sub-transmission
31.0316
Transmission41.0215

Demand - For Peak Load CalculationsVoltage CodeEffective 6/1/2014
Secondary11.08199
Primary21.06076
Sub-transmission31.03841
Transmission41.02840